[QB-973] QuickBuild UI is unresponsive when one of the nodes is not answering
|
|
Status: | Closed |
Project: | QuickBuild |
Component/s: | None |
Affects Version/s: | 3.1.25 |
Fix Version/s: | 3.1.51 |
Type: | Bug | Priority: | Critical |
Reporter: | Pini Reznik | Assigned To: | Robin Shen |
Resolution: | Fixed | Votes: | 0 |
Remaining Estimate: | Unknown | Time Spent: | Unknown |
Original Estimate: | Unknown | ||
Environment: |
System Date and Time 2011-07-04 17:09:07
Operating System Linux 2.6.16.60-0.21-smp, amd64 JVM Java HotSpot(TM) 64-Bit Server VM 19.0-b09, Sun Microsystems Inc. QuickBuild Version 3.1.25 - Fri Mar 04 07:41:30 CET 2011 |
Description |
When one of the node is not answering but it is still up (for example extremely overloaded) and I click on the 'grid' tab, the whole QB UI is not responding.
I can see following in the logs: 2011-07-04 16:44:36,640 [Thread-3534754] WARN com.pmease.quickbuild.DefaultBuildEngine - Error caching build status in grid node '{agent-name:8811}'. com.caucho.hessian.client.HessianRuntimeException: Can not connect to 'http://10.18.120.30:8811/service/node'. at com.caucho.hessian.client.HessianProxy.sendRequest(HessianProxy.java:321) .... Caused by: java.net.SocketTimeoutException: connect timed out at java.net.PlainSocketImpl.socketConnect(Native Method) After timeout (few minutes) I can see the grid again the the problematic node is shown like this: agent-name:8811 build agent 10.18.120.30 false 10 unknown 10000 |
Comments |
Comment by Robin Shen [ 05/Jul/11 12:16 AM ] |
This has been fixed in latest QuickBuild version. Please have a try. |