Description |
Variables on promoted builds should automatically be inherited unless the configuration you are promoting to explicitly defines that variable for itself. In that case you must explicitly tag the variable to override the promotion target's configuration variable.
Promotions should carry as much information forward as possible, so you know exactly what build you are working with. |
Comments |
Comment by Jared Stutesman [ 07/Oct/10 03:05 PM ] |
For example:
root/config1: defines: var1="childVar1" var2="childVar2" var3="childVar3" - this variable explicitly tagged to promote root/configTarget: defines: var2 = "targetVar2" var3 = targetVar3" when a build is promoted from root/config1 to root/configTarget it should be left with: var1="childVar1" - this variable is automatically inherited var2="targetVar2" - this variable is not inherited because it is defined configTarget var3="childVar3" - this variable overrides the configTarget value because it was explicitly set to override |
Comment by Robin Shen [ 10/Oct/10 04:39 AM ] |
This issue is now fixed in 3.0.11. However the explicit flag to carry over variable is not used for easy understanding of variable definition. To override variables already defined in destination configuration, user needs to specify the variable when define the promotion. |
Comment by Robin Shen [ 30/Jul/11 01:00 PM ] |
Unfortunately we have to revert this change due to several feedbacks from other customers. Refer to |
Comment by Anais Gonzalez [ 05/Aug/11 06:39 PM ] |
We have extensive automation and configurations that depend on this functionality being present. They have been working for months and it would greatly hinder our automation process if we lost this to the point that we are now considering switching to either a different system or just stop updating Quickbuild indefinitely. Please either put that functionality back or help us by providing a patch we could use to get it back. As it stands right now, it's greatly hindering our ability to use your product. |
Comment by Jared Stutesman [ 05/Aug/11 08:09 PM ] |
It looks like |
Comment by Robin Shen [ 19/Aug/11 08:23 AM ] |
An option is added in promotion definition in 3.1.56 to optionally enable/disable this feature. |
Comment by Martin [ 11/Nov/16 07:00 AM ] |
Where is this option to enable/disalbe this feature in QB 6.0? I can see only the one for prompted configuration variables |